Intermittent injection of prepolymer in a pressurized fluidized bed
Inclined, intermittent jets can be used to feed solids into fluidized beds. In this report the injection system was successfully modeled.
Inclined, intermittent jets can be used to feed solids into fluidized beds. In this report the injection system was successfully modeled.
Non-mechanical valves, especially the L-valves, have been used extensively in fluidized beds and circulating fluidized beds for solids recycling or to serve as a pressure seal. This paper presents a set of L-valve equations which relate the solids flow rate to the L-valve design, aeration rate, and pressure drop across the L-valve.
Accurate predictions of both the flux and size distribution of the solids entrained above the transport disengaging height of a fluidized bed are necessary. A new correlation was developed to calculate size distribution and flux of entrained particles.